Model CDS-SR5V Cylindrical Type Capacitive Proximity Sensor
- Product catalog download
- 3D PDF Download
- CDS-SR5V Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- Detection of rice grains, cereales, bran, wood, powders, liquids, etc.
- Liquid level detection chemicals, such as water
- Presence detection of food within the package
Features
- High-sensitivity electrostatic-capacity proximity sensor that can detect almost any target regardless of the material.
- Shaped as an M22 P1.5 plastic screw for easy installation and position adjustment.
- Equipped with a 18-turn trimmer potentiometer to adjust the sensitivity.
- The interior is filled with solid plastic to increase robustness.
- Shielded type that can be used even when embedded in metal.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating / Performance / Characteristics Graph
Rating / Performance
| Model | CDS-SR5V | CDS-SR5V1 |
|---|---|---|
| Detection Surface | Front side detection | |
| Detection Distance | 5 mm | |
| Hysteresis | 10% or less of the detection distance | |
| Detection Distance Variable Range | 2.5 to 5.0 mm | |
| Detection Target Target |
Grounded metal of 50 × 50 mm and 1 mm in thickness | |
| Power Voltage | 12 V to 24 V DC (Operating voltage range : 10 V to 30 V DC) | |
| Power Consumption | 10 mA DC or less | |
| Output | NPN transistor open collector 30 V DC, 100 mA DC or less | |
| Output Residual Voltage | 1 V DC or less (Load current 100 mA DC) | |
| Operation Status | Normally open (On output with detection target) |
Normally closed (Off output with detection target) |
| Operation Indication | Red LED (Lit when On output) | |
| Response Frequency | 50 Hz or more | |
| Temperature Range Range |
-10 to 55 °C (-15 to 60 °C during storage) (Without dew condensation or freezing) |
|
| Humidity Range Range |
35 to 95% RH (35 to 95% RH during storage)(Without dew condensation) | |
| Breakdown Voltage | 500 V AC, 50/60 Hz for 1 min (Between live parts and the case) | |
| Insulation Resistance | 50 MΩ or more, at 500 V DC megger (Between live parts and the case) | |
| Vibration Resistance | Durability : 10 to 55 Hz, Double amplitude: 1.5 mm in X-, Y-, and Z-direction, each 2 hours (Device not powered) | |
| Shock Resistance | Durability : 500 m/s² (Approx. 50 G) in X-, Y-, and Z-direction, each 3 times (Device not powered) |
|
| Ingress Protection | IP65 | |
| Case Material | ABS (Hex nut : PBT, Rubber washer : NBR) | |
| Cable | ø4, 3-core round cord of 0.2 mm² and insulation 1.1 mm and 1 m in length (Oil and heat resistant) |
|
| Weight | Approx. 52 g (Without accessories) | |
| Accessories | 2 hex nuts (plastic), 2 rubber washers, 1 slotted screwdriver for adjustment | |
*For a detailed specification of the other, please refer to specifications.
Characteristics Graph (Typical Example)

External Dimensions Diagram / Output Circuit
External Dimensions Diagram

Output Circuit

Usage Precautions
About common mode noise prevention of capacitive type proximity sensors
Typical sources of common mode noise are as follows (including wiring of each):
・Inverter devices (power supplies for inverter motors and pulse motors)
・Vibration generators
・Switching power supplies
・Wireless devices
・Microwave generators
・Large power transmission antennas
To prevent the generation of common mode noise, it is essential to ground near these noise sources.
To avoid common mode noise generation in the sensor power line, connect the sensor ground (GND, 0V) either directly to ground, or to ground via a 1,000 pF or higher capacitor of sufficient withstand voltage, or else to the frame ground (F.G.) with sufficient capacitance to ground. When connecting the sensor to ground via the sensor housing, ensure correct electrical bonding to avoid contact resistance.There is also another type of noise referred to as normal mode noise (or differential mode noise) which is generated in-between the power lines. If the current, cable loop area, and frequency are the same, common mode noise is much larger by around 100 times (100 MHz) to 10,000 times (1 MHz) compared to normal mode noise. Accordingly, a countermeasure of simply separating the line experiencing the common mode noise from the sensor wiring is insufficient and not recommended.To avoid common mode noise, use a shielded cable, or more effectively, adequate shield grounding should be used.
Influence of Surrounding Metal

Mutual Interference

Installation
Tighten the case with a torque of 0.5 N.m or less.
Other
See proximity sensor general usage precautions for other precautions.
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
| Model Name | Output configuration | Standard Price | Inventory Type | Select |
|---|---|---|---|---|
| CDS-SR5V | Normally open |
45 USD
42 EUR
|
STD | |
| CDS-SR5V1 | Normally closed |
45 USD
42 EUR
|
WIP |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.