Model EIC-122EA 2-axis Inclination Sensor
- Product catalog download
- 3D PDF Download
- EIC-122EA Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- (Slope in case of theft) anomaly detection of vehicle
- Security of mechanical instruments
- Detection of air conditioner flap inclination
- Anomaly detection of level crossing barrier
Features
- High accuracy with ±1.0 % of FS linearity.
-
The output voltage does not vary according to the power supply variation thanks to the built-in constant voltage circuit.
- Detection possible on two axes, x axis and y axis.
- Resistant to irradiated electromagnetism thanks to its internal shield.
- Waterproof connector can be used.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating/Performance/Characteristics Graph
Rating / Performance
Model | EIC-122EA | ||
---|---|---|---|
Detection Inclination
Range
|
± 25° (Detection width of 50°) | ||
Power Supply Voltage | 12 V to 24 V DC (Operating voltage range : 10.8 V to 30 V DC) | ||
Power Consumption | 15 mA DC or less (With 12 V DC, 25°C) | ||
Output | Output Voltage | 0.5 V to 4.5 V DC ± 0.15 V (At 12 VDC,25 °C) (By placing the 0 ° fixed one axis) |
|
Horizontal Voltage | 2.5 V DC ± 0.1 V(At 12 V DC,25 °C) | ||
Linearity | ±1% FS or less | ||
Response Time | 0.18 seconds (Time constant for step response at 25 °C) | ||
Load Resistance | 100 kΩ or more | ||
Operating Temperature
Range
|
-20 to 70 °C (-25 to 75 °C during storage) (Without dew condensation or freezing) |
||
Operating Humidity
Range
|
35 to 95% RH (35 to 95% RH during storage)(Without dew condensation) | ||
Withstand Voltage | 1 min at 500 V AC 50/60 Hz (Between the live part and installation part) | ||
Insulation Resistance | 100 MΩ or more measured with an ohmmeter at 500 V DC (Between the live part and installation part) |
||
Vibration Resistance | Durability : 2 hours in each X, Y, Z direction at 10 to 55 Hz and with peak-to-peak amplitude of 1.5 mm (At power off) | ||
Shock Resistance | Durability : 3 times at 1000 m/s² (approx. 100 G) in each X, Y, Z direction (At power off) |
||
Electromagnetic
Field Strength
|
ISO 11452-2 (200 MHz to 1 GHz) 100 V/m : Output variation of ± 3% of FS or less
ISO 11452-3 (10 MHz to 200 MHz) 100 V/m : Output variation of ± 1% of FS or less
|
||
Protection Rating | IP67 | ||
Case Material | ABS | ||
Cable | ø6.6, 4-core round cord of 0.5 mm² and 1 m in length (VCTF) | ||
Weight | Approx. 91 g |
*For a detailed specification of the other, please refer to specifications.
Characteristics Graph (Typical Example)
External Dimensions Diagram/Output Circuit
External Dimensions Diagram
Output Circuit
- See Inclination sensors general usage precautions for the usage precautions.
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
Model Name | Cable length | Standard Price | Inventory Type | Select |
---|---|---|---|---|
EIC-122EA | 標準 |
78 USD
72 EUR
|
STD |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.