Model MDS-G25-2M Groove(U) Type Inductive Sensor
- Product catalog download
- 3D PDF Download
- MDS-G25-2M_EN Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- Detection of objects with large vibrations
- Detection of large moving object
Features
- Comes with a 4.7k Ω pull-up resistor. (Please consult if you require an open-collector output.)
- Detects the passage of all types of metals.
- Perfect to detect the number of rotations of metal sheet slitters or gears.
- Supports high-speed detection.
- The unit is equipped with a LED display for clear indication of operation status.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating/Performance
Rating / Performance
| Model | MDS-G25-2M | MDS-G25B-2M | ||
|---|---|---|---|---|
| Detection Groove Width | 25 mm | |||
| Detection Distance | 12 ± 2 mm | |||
| Detection Position | * 15 mm (Distance between the inductive target and the bottom of the sensor groove) | |||
| Standard Detection Target | Iron sheet of 50 × 50 mm and 2.3 mm in thickness (Detects both magnetic and non-magnetic metals) |
|||
| Hysteresis | * 2 mm or less | |||
| Power Supply Voltage | 12 V to 24 V DC (Operating voltage range : 10 V to 30 V DC) | |||
| Current Consumption | 28 mA DC or less | |||
| Output | NPN transistor with 4.7k Ω pull-up resistor 30 V DC, 100 mA DC or less | |||
| Output Residual Voltage | 1.5 V DC or less (Load current 100 mA DC) | |||
| Operation Status | Normal "H"(ON output when detecting) | |||
| Operation Indicator | Orange LED (Lit when the output is ON) | Green LED (Lit when the output is ON) | ||
| Response Frequency | 1 kHz or more(Detector width: at least 50 mm, Width of slit: at least 50 mm, Thickness: 1 mm) | |||
| Temperature Range | -25 to 70 °C (-30 to 75 °C storage temperature range) (Without dew condensation or icing) | |||
| Humidity Range | 95 % RH or less (95 % RH storage humidity range) (Without dew condensation) | |||
| Dielectric Strength | 2000 V AC for 1 minute (Between the live part and case) | |||
| Insulation Resistance | 50 MΩ or more at 500 V DC megger (Between the live part and case) | |||
| Vibration Resistance | 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions for 2 hours each (at power off) | |||
| Shock Resistance | 500 m/s² (Approx. 50 G) in X, Y and Z directions 10 times each (at power off) | |||
| Protection | IP67 | |||
| Case Material | Polyarylate | |||
| Cable | Cable : ø6, 3-core round cord of 0.5 mm² and insulation 1.9 mm and 2 m in length (Oil and heat resistant vinyl) | |||
| Weight | Approx. 240 g | |||
*See Detection distance conditions on the next item.
Detection Distance Conditions
The detection distance is measured by placing a detection target (a 50 x 50 x t 2.3 iron plate) 15 mm from the groove bottom surface of the case, inserting it toward the center of the case, and measuring the distance from the point X at which output turns ON. The hysteresis is measured by returning the detection target from the point at which output turns ON and measuring the distance to the point at which the output turns OFF.
Outline Dimensions/Output Circuit
Outline Dimensions

Output Circuit

*Because there is no reverse connection protection diode built-in, pay careful attention to the polarity of the power supply.
Precautions During Use
Influence of Surrounding Metal
If there are metal objects around the inductive sensor, leave at least the space indicated in the figure below between them and the sensor.

Mutual Interference
If you use a number of the same product, separate them at least by the distances shown in the figure below to prevent reciprocal interference. *The figures in parentheses are for combinations of different frequency sensors.

Mounting
Always use plain washers to tighten the case and use a torque of 0.5 N·m or less.
Other
See inductive sensor general Precautions During Use for other precautions.
*For a detailed specification of the other, please refer to specifications.
Quote / Order
Quote / Order
Please contact our sales.