Model MDA-F10U Proximity Displacement Sensor
- Product catalog download
- 3D PDF Download
- MDA-F10U Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- Displacement measurement of magnetic metal
- Pressure measurement using a magnetic metal actuator
- Amplitude measurement using a magnetic metal actuator
- Detection of two-sheets feed error using a magnetic metal actuator
Features
- Economical linear-output proximity displacement sensor.
- No mechanical parts to increase the lifespan.
- Molded type that can be used safely even in places where water may splash.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating / Performance
Rating / Performance
Model | MDA-F10U | |
---|---|---|
Detection Surface | Upper side detection | |
Detection Distance | 2 to 10 mm | |
Detection Target | Steel plate of 50 × 50 mm and 1 mm in thickness | |
Power Voltage | 12 V to 24 V DC (Operating voltage range : 10.8 V to 26.4 V DC) | |
Voltage Characteristics | ±0.3 % FS or less of detection distance within the power supply voltage 12 V to 24 V DC of ±10 % | |
Power Consumption | 10 mA DC or less | |
Output | Output resistance 10 kΩ, linear output The reference point is 2 mm ± 0.2 mm in front of the sensor detection surface, and the output value is 1 V. 5 V ±0.1 V with standard point +8 mm output with no detection target, max output voltage 7.2 V |
|
Linearity | ± 4 % / FS or less (At 25 ℃) | |
Response Time | 1 ms or less | |
Temperature Range | -10 to 60 °C (-20 to 60 °C during storage) (Without dew condensation or freezing) |
|
Temperature Characteristic | ±7 % FS or less of detection distance at 25 °C, in the temperature range(-10 to 60 °C) | |
Humidity Range | 85 % RH (85 % RH during storage)(Without dew condensation) | |
Breakdown Voltage | 500 V AC, 50/60 Hz for 1 min (Between live parts and the case) | |
Insulation Resistance | 50 MΩ or more, at 500 V DC megger (Between live parts and the case) | |
Vibration Resistance | Durability : 10 to 55 Hz, Double amplitude: 1.5 mm in X-, Y-, and Z-direction, each 2 hours (Device not powered) | |
Shock Resistance | Durability : 200 m/s² (Approx. 20 G) in X-, Y-, and Z-direction, each 3 times (Device not powered) | |
Ingress Protection | IP67 | |
Case Material | Polyarylate resin | |
Cable | ø6.1, 3-core round cord of 0.5 mm² and insulation 1.9 mm and 1 m in length (Oil and heat resistant) | |
Weight | Approx. 170 g |
Characteristics Graph
Detection Distance - Output Voltage Characteristics (SPC : 50 mm × 50 mm t=1)
Size - Output Voltage of Iron Plate Detector (SPC) Characteristics
Material - Output Voltage Characteristics
Usage Precautions
Influence of Surrounding Metal
If there are metal objects around the sensor, leave at least the space indicated in the figure below between them and the sensor.
Mutual Interference
When two or more identical sensors are used, observe the minimum values shown in the figure below to prevent mutual interference.
(Sensors with a different frequency are indicated with a B or C after the model name.)
Installation
Be sure to use a plain washer, and ensure that the tightening torque is 0.5 Nm or less.
Other
- The 1 V output point is the reference point. Do not use below 1 V.
- The characteristics of the detection target whose surface is plated are changed by the high frequency skin effect. Please confirm the characteristics of the sensor with actual equipment before using.
- Even in the case of iron materials, detection characteristics may differ depending on the composition ratio of the content. Please confirm the characteristics of the sensor with actual equipment before using.
See proximity sensor general usage precautions for other precautions.
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
Model Name | Frequency | Standard Price | Inventory Type | Select |
---|---|---|---|---|
MDA-F10U | Normal type |
96 USD
88 EUR
|
BTO | |
MDA-F10UB | First different frequency type |
96 USD
88 EUR
|
BTO | |
MDA-F10UC | Second different frequency type |
96 USD
88 EUR
|
BTO |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.