Model GIW-*-5 Security Shock Sensor, Power Voltage 5 V DC
- Product catalog download
- 3D PDF Download
- GIW_EN Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- Excellent environmental protection. The sensor section is built to the IP67 standard and can be used in environments where dust or water is present. Waterproof connectors can also be used.
- Single-axis impact sensor.
- Vibration sensing frequency range from 10Hz to 1kHz.
- Ideal for crime prevention, acceleration monitoring, such as caused by impact shock, breakage and object movement.
- Sensitivity is reduced for high-frequency vibration generated from the machine, preventing false detection due to high-frequency vibration.
- Even momentary impacts can be detected.
Features
- Equipment impact monitoring
- Security sensors (Theft prevention, intrusion detection, etc.)
- Shock detection switches
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating/Performance/Frequency Characteristics
Rating / Performance
Model | GIW-*-5 | GIW-*1-5 | |
---|---|---|---|
Power Voltage | 5 V DC ± 5 % | ||
Power Consumption | 5 mA DC or less | ||
Output | N-channel MOSFET Open drain 30 V DC, 100 mA DC or less, (Output is available 800 ms from power ON) |
||
Output-Residual Voltage | 1 V DC or less (Load current 100 mA DC) | ||
Operation Status | Normally open (Output ON when shock is detected) |
Normally closed (Output OFF when shock is detected) |
|
Output Hold Time
|
Momentary Shock Input | ON for at least 80 ms (When input time is 3 ms or more) ON for 80 ms or less (When input time is less than 3 ms) |
OFF for at least 80 ms (When input time is 3 ms or more) OFF for 80 ms or less (When input time is less than 3 ms) |
At Continuous Shock Input |
Continuous ON | Continuous OFF | |
Detection Frequency | 10 Hz to 1 kHz | ||
Response Time | 4 ms or less | ||
Circuit Protection | Output surge absorption diode | ||
Temperature Range | -10 ºC to 60 ºC (At storage: -15 ºC to 65 ºC) (Without dew condensation or freezing) |
||
Humidity Range | 95% RH or less (At storage: 95 % RH or less)(Without dew condensation) | ||
Breakdown Voltage | 500 V AC, 50/60 Hz for 1 min (Between live parts and mountings) | ||
Insulation Resistance | 20 MΩ or more, At 500 V DC megger (and mountings) Between live parts | ||
Vibration Resistance | Durability: 10 to 55 Hz, Double amplitude: 1.5 mm in X-, Y-, and Z-direction, each 2 hours (Device not powered) | ||
Shock Resistance | Durability: 500 m/s² (Approx. 50 G) in X-, Y-, and Z-direction, each 3 times (Device not powered) | ||
Ingress Protection | IP67 | ||
Case Material | ABS reinforced with glass-fiber (*It is possible to change to a case made of m-PPE material, which has excellent oil resistance and chemical resistance.) |
||
Cable | ø4, 3-core round cord of 0.3 mm² and insulation 1.5 mm and 1 m in length (Oil and heat resistant) |
||
Weight | Approx. 30 g |
Detection Sensitivity
Model | GIW -1-5 |
GIW- 1H-5 |
GIW- 2-5 |
GIW- 3-5 |
GIW- 5-5 |
GIW- 7-5 |
GIW- X3-5 |
GIW- 15-5 |
GIW- 20-5 |
|
---|---|---|---|---|---|---|---|---|---|---|
GIW -11-5 |
GIW- 1H1-5 |
GIW- 21-5 |
GIW- 31-5 |
GIW- 51-5 |
GIW- 71-5 |
GIW- X31-5 |
GIW- 151-5 |
GIW- 201-5 |
||
Detection-
Sensitivity
|
30 Hz | 1 G ± 25 % |
1.5 G ± 20 % |
2 G ± 20 % |
3 G ± 20 % |
5 G ± 20 % |
7 G ± 20 % |
10 G ± 20 % |
15 G ± 20 % |
20 G ± 20 % |
100 Hz Reference |
2.0G ± 30 % |
2.9 G ± 25 % |
4.0 G ± 25 % |
6.3 G ± 25 % |
10.5 G ± 25 % |
16.4 G ± 25 % |
20.7 G ± 25 % (70Hz) |
24.4 G ± 25 % (60Hz) |
25.5 G ± 25 % (50Hz) |
Note : Please feel free to consult us regarding any different requirements you may have to those specified above, for detection sensitivity,power voltage, output retenti
Reference Frequency Characteristics (Typical)
Dimensions/Output Circuit
Dimensions
Output Circuit
*Because there is no reverse connection protection diode built-in, pay careful attention to the polarity of the power supply.
Precautions During Use
- Always use plain washers to tighten the case and use a torque of 0.32 N·m or less.
- The normal closed output type takes 100 ms maximum from power ON to output turn-ON.
- Thermal shock applied to the sensor during an abrupt temperature change can change the detection sensitivity.Ensure proper handling of the sensor.
- Usage when the cable is subjected to stress or vibration due to impacts may cause disconnection or malfunction. Secure the cable lead-out so that no stress or vibration can be applied.
- Because there is no reverse connection protection diode built-in, pay careful attention to the polarity of the power supply.
- For other precautions during use, refer to the General Precautions for shock sensor.
*It is possible to change to a case made of m-PPE material, which has excellent oil resistance and chemical resistance. We also accept changes to cable length, weatherproof case, and cable material. Please contact us.
*For other detailed specifications, refer to the specification sheet of the corresponding model.
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
Model Name | Operation Configuration | Detection sensitivity | Standard Price | Inventory Type | Select |
---|---|---|---|---|---|
GIW-1-5 | Normally open | 1 G |
38 USD
35 EUR
|
BTO | |
GIW-1H-5 | Normally open | 1.5 G |
38 USD
35 EUR
|
BTO | |
GIW-2-5 | Normally open | 2 G |
38 USD
35 EUR
|
BTO | |
GIW-3-5 | Normally open | 3 G |
38 USD
35 EUR
|
STD | |
GIW-5-5 | Normally open | 5 G |
38 USD
35 EUR
|
STD | |
GIW-7-5 | Normally open | 7 G |
38 USD
35 EUR
|
STD | |
GIW-X3-5 | Normally open | 10 G |
38 USD
35 EUR
|
STD | |
GIW-15-5 | Normally open | 15 G |
38 USD
35 EUR
|
STD | |
GIW-20-5 | Normally open | 20 G |
38 USD
35 EUR
|
STD | |
GIW-11-5 | Normally closed | 1 G |
38 USD
35 EUR
|
BTO | |
GIW-1H1-5 | Normally closed | 1.5 G |
38 USD
35 EUR
|
BTO | |
GIW-21-5 | Normally closed | 2 G |
38 USD
35 EUR
|
BTO | |
GIW-31-5 | Normally closed | 3 G |
38 USD
35 EUR
|
BTO | |
GIW-51-5 | Normally closed | 5 G |
38 USD
35 EUR
|
BTO | |
GIW-71-5 | Normally closed | 7 G |
38 USD
35 EUR
|
BTO | |
GIW-X31-5 | Normally closed | 10 G |
38 USD
35 EUR
|
BTO | |
GIW-151-5 | Normally closed | 15 G |
38 USD
35 EUR
|
BTO | |
GIW-201-5 | Normally closed | 20 G |
38 USD
35 EUR
|
BTO |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.