Model PY2-*5 Pyroelectric Infrared Sensor
- Product catalog download
- 3D PDF Download
- PY2-5_EN Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- Human presence detection
- Sensors used for crime prevention (e.g. security camera activation)
- Automatic switching (e.g. lighting, ventilation fan)
- Energy saving
Features
- Contributing to energy savings in equipment with low power consumption (50uW or less at 3V).
- A small, easy-to-install human presence sensor.
- The S / N ratio optimization circuitry improves sensitivity while reducing malfunctions.
- Ample timer time is available.
- The type with ambient light sensor can be useful for night-time monitoring.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating/Performance/Detection Area
Rating / Performance
Model | PY2-S5 | PY2-M5 | PY2-L5 | PY2-S5P | PY2-M5P | PY2-L5P |
---|---|---|---|---|---|---|
Human Presence Sensor | Pyroelectric Sensor (Dual element) | |||||
Ambient Light Sensor | Not included | Included | ||||
Power Voltage | 3 to 5 V DC (Operating voltage range : 2.7 V to 5.5 V DC) | |||||
Standby Current Consumption | Typ : 8 uA | Typ : 10 uA | ||||
Operating Current Consumption | Typ : 13 uA | Typ : 15 uA | ||||
Current Consumption When LED Lit |
Max : 180 uA or less | Max : 185 uA or less | ||||
Output | N-channel MOSFET Open drain 30V DC 80mA DC or less | |||||
Output Residual Voltage | 1 V DC or less (Load current 80 mA DC) | |||||
Startup Output Latency | Approx. 35 sec | |||||
Timer Time | 10 to 30 sec | 30 to 90 sec | 60 to 180 sec | 10 to 30 sec | 30 to 90 sec | 60 to 180 sec |
Ambient Light Sensor Sensitivity | - | Approx. 100 Lx | ||||
Temperature Range | 0 to 50 °C (-10 to 60 °C during storage)(Without dew condensation or freezing) | |||||
Humidity Range | 85 % RH (85 % RH during storage) (Without dew condensation) | |||||
Breakdown Voltage | 500 V AC, 50/60 Hz for 1 min (Between live parts and the case) | |||||
Insulation Resistance | 50 MΩ or more, at 500 V DC megger (Between live parts and the case) | |||||
Vibration Resistance | Durability : 10 to 55 Hz, Double amplitude: 1.5 mm in X-, Y-, and Z-direction, each 2 hours (Device not powered) | |||||
Shock Resistance | Durability : 500 m/s² (Approx. 50 G) in X-, Y-, and Z-direction, each 3 times (Device not powered) | |||||
Ingress Protection | IP 50 | |||||
Material | Case : PMMA, Fresnel Lens : Polyethylene | |||||
Connector | Connector: SM03B-GHS (3-pin)(Manufactured by J.S.T Connector) [Connections]Housing: GHR-3-03V-S, Contact: SSHL-002T-P0.2 (Manufactured by J.S.T Connector) |
|||||
Weight | Approx. 10 g | |||||
Options (Sold Separately) | Connector harness: CNH-GHR03S28-300 |
Detection Area
Dimensions/Connector Harness/Output Circuit/Timing Chart
Dimensions
Connector Harness (Sold Separately)
Output Circuit
Timing Chart
Precautions During Use
- The pyroelectric infrared sensor detects changes in the heat (infrared) emitted by the human body.
A person in a static condition cannot be detected. - May detect changes in heat sources other than the human body (such as from small animals).
- May react in locations where there is rapid air movement, such as in air conditioners, or to the swaying of a curtain or blind.
- Detection is not possible through obstructions such as glass or acrylic plastic.
- This sensor cannot be used outdoors.
Even in indoors, the sensor cannot be used in places where sunlight enters or where temperature changes rapidly. - After the detection area is vacated, when the timer time elapses and the output turns OFF.
The output is turned on, when human presence is detected again.
Sensor turns OFF after the timer time has elapsed from the last detection time. - May not work properly if there is dirt, dust, scratches, or other foreign substances are on the lens.
- For other precautions, please refer to "General Precautions" of Pyroelectric infrared sensors.
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
Model Name | Illuminance Sensor | Timer Time | Standard Price | Inventory Type | Select |
---|---|---|---|---|---|
PY2-S5 | Not included | 10 to 30 sec |
31 USD
29 EUR
|
BTO | |
PY2-M5 | Not included | 30 to 90 sec |
31 USD
29 EUR
|
STD | |
PY2-L5 | Not included | 60 to 180 sec |
31 USD
29 EUR
|
STD | |
PY2-S5P | Included | 10 to 30 sec |
32 USD
30 EUR
|
STD | |
PY2-M5P | Included | 30 to 90 sec |
32 USD
30 EUR
|
BTO | |
PY2-L5P | Included | 60 to 180 sec |
32 USD
30 EUR
|
BTO |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.