Model GIS-A5 Compact Shock (Acceleration) Sensor, Power Voltage 5 V DC
- Product catalog download
- 3D PDF Download
- GIS-A5_EN Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- Vibration monitoring of electrical appliances
- Vibration monitoring of gaming devices
- Security of equipment/machines
- Building security
Features
- The sensor can detect the impact and acceleration of 1 kHz or less almost flat.
- A locking connector securely prevents disconnection of connectors caused by wire runs or vibration. A clear click touch when fitted together ensures complete insertion.
- There are two output types: normally open, and normally closed, which can detect leadwire disconnection.
- Momentary shocks of 200 ms or more can be detected.
- A different detection sensitivity other than that for the standard model is also available. Feel free to contact us.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating/Performance/Frequency Characteristics
Rating / Performance
Model | GIS-*5 | GIS-*15 | |
---|---|---|---|
Power Supply Voltage | 5 V DC ±5%(absolute maximum rating:30 V DC)*1 | ||
Current Consumption | 6 mA DC or less | ||
Output | Nch MOSFET Open drain | NPN bipolar transistor, Open collector | |
30 V DC, 50 mA DC or less, (Output is available 700 ms from power ON) | |||
Output Residual Voltage | 1 V DC or less (Load current 50 mA DC) | ||
Operation Status | Normally open (Output ON when shock is detected) |
Normally closed (Output OFF when shock is detected) |
|
Output Hold Time
|
Momentary Shock Input | ON for at least 200 ms (When input time is 3 ms or more) ON for 200 ms or less (When input time is less than 3 ms) |
OFF for at least 200 ms (When input time is 3 ms or more) OFF for 200 ms or less (When input time is less than 3 ms) |
At Continuous Shock Input |
Continuous ON | Continuous OFF | |
Detection Frequency | 10 Hz to 1 kHz | ||
Response Time | 4 ms or less | ||
Circuit Protection | Output surge absorption diode | ||
Temperature Range | -10 ºC to 60 ºC (-15 ºC to 65 ºC storage temperature range)(Without dew condensation or icing) | ||
Humidity Range | 85% RH or less (85 % RH or less storage humidity range)(Without dew condensation or icing) | ||
Dielectric Strength | 500 V AC for 1 minute (Between live parts and the mounting part) | ||
Insulation Resistance | 20 MΩ or more at 500 V DC megger (Between live parts and the mounting part) | ||
Vibration Resistance | 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions for 2 hours each (at power off) | ||
Shock Resistance | 500 m/s² (Approx. 50 G) in X, Y and Z directions 3 times each (at power off) | ||
Protection | IP50 | ||
Case Material | ABS resin with glass | ||
Connector | Connector: SM03B-GHS(3-pin)(from J.S.T. Mfg. Co.,Ltd.) [Connections]Housing: GHR-03V-S, Contact: SSHL-002T-P0.2 (from J.S.T. Mfg. Co.,Ltd.) |
||
Weight | Approx. 4 g | ||
Options (Separately Supplied) |
Connector harness: CNH-GHR03S28-300 |
*1: It is a limit value with which the product is free from breakage. It does not guarantee the above-mentioned rating/performance.
Detection Sensitivity
Model | GIS-A5 | GIS-B5 | GIS-C5 | GIS-D5 | GIS-E5 | GIS-F205 |
---|---|---|---|---|---|---|
GIS-A15 | GIS-B15 | GIS-C15 | GIS-D15 | GIS-E15 | GIS-F2015 | |
Detection Sensitivity | 1G±20 % (At 500Hz) |
3G±20% (At 500Hz) |
5G±20% (At 500Hz) |
7G±20% (At 500Hz) |
10G±20% (At 500Hz) |
20G±20% (At 500Hz) |
Reference Frequency Characteristics (Typical)
Outline Dimensions/Connector Harness/Output Circuit
Outline Dimensions
Connector Harness(Separately Supplied)
Output Circuit
Precautions During Use
- Always use plain washers to tighten the case and use a torque of 0.32 N.m or less.
- The normal closed output type takes 300 ms maximum from power ON to output turn-ON.
- Thermal shock applied to the sensor during an abrupt temperature change can change the detection sensitivity. Ensure proper handling of the sensor.
- Avoid subjecting the sensor wire harness to mechanical stress while connecting to the connector or allowing vibration to transferred from impact, otherwise disconnection or malfunction may result. Support the harness lead-out so that it is not subjected to excessive stress or vibration.
- Because there is no reverse connection protection diode built-in, pay careful attention to the polarity of the power supply.
- For other precautions during use, refer to the General Precautions for shock sensor.
*For other detailed specifications, refer to the specification sheet of the corresponding model.
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
Model Name | Output configuration | Detection sensitivity | Standard Price | Inventory Type | Select |
---|---|---|---|---|---|
GIS-A5 | Normally open | 1 G |
13 USD
12 EUR
|
STD | |
GIS-B5 | Normally open | 3 G |
13 USD
12 EUR
|
STD | |
GIS-C5 | Normally open | 5 G |
13 USD
12 EUR
|
STD | |
GIS-D5 | Normally open | 7 G |
13 USD
12 EUR
|
STD | |
GIS-E5 | Normally open | 10 G |
13 USD
12 EUR
|
STD | |
GIS-F205 | Normally open | 20 G |
13 USD
12 EUR
|
STD | |
GIS-A15 | Normally closed | 1 G |
13 USD
12 EUR
|
BTO | |
GIS-B15 | Normally closed | 3 G |
13 USD
12 EUR
|
BTO | |
GIS-C15 | Normally closed | 5 G |
13 USD
12 EUR
|
BTO | |
GIS-D15 | Normally closed | 7 G |
13 USD
12 EUR
|
BTO | |
GIS-E15 | Normally closed | 10 G |
13 USD
12 EUR
|
BTO | |
GIS-F2015 | Normally closed | 20 G |
13 USD
12 EUR
|
BTO |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.