Model GIS-1 Security Compact Shock Sensor, Power Voltage 10 V to 30 V DC
- Product catalog download
- 3D PDF Download
- GIS-1_EN Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- Vibration monitoring for electronic devices
- Monitoring of vibration to the game machine
- Security of mechanical instruments
- Building security
Features
- Monitors simple impacts caused intentionally. Avoid incorrect detection remove in high frequencies.
- Uses connector with lock for prevent the missing connector according to routing of the wire or vibration.
- Perfect installed on glass windows to monitor impacts for security or on game machines to detect inappropriate actions such as a hit.
- Can detect instant impacts and output them for more than 200 ms using a multivibrator circuit.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating/Performance/Frequency Characteristics
Rating / Performance
| Model | GIS-* | GIS-*1 | |
|---|---|---|---|
| Power Supply Voltage | 10 V to 30 V DC | ||
| Current Consumption | 8 mA DC or less | ||
| Output | Nch MOSFET Open drain | NPN bipolar transistor, Open collector | |
| 30 V DC, 50 mA DC or less, (Output is available 700 ms from power ON) | |||
| Output Residual Voltage | 1 V DC or less (Load current 50 mA DC) | ||
| Operation Status | Normally open (Output ON when shock is detected) |
Normally closed (Output OFF when shock is detected) |
|
|
Output Hold Time
|
Momentary Shock Input | ON for at least 200 ms (When input time is 3 ms or more) ON for 200 ms or less (When input time is less than 3 ms) |
OFF for at least 200 ms (When input time is 3 ms or more) OFF for 200 ms or less (When input time is less than 3 ms) |
| At Continuous Shock Input |
Continuous ON | Continuous OFF | |
| Detection Frequency | 10 Hz to 1 kHz | ||
| Response Time | 4 ms or less | ||
| Circuit Protection | Back-flow protection diode and output surge absorption diode | ||
| Temperature Range | -10 to 60 °C (-15 to 65 °C storage temperature range)(Without dew condensation or icing) | ||
| Humidity Range | 85 % RH or less (85 % RH or less storage humidity range)(Without dew condensation) | ||
| Dielectric Strength | 500 V AC for 1 minute (Between live parts and the mounting part) | ||
| Insulation Resistance | 20 MΩ or more at 500 V DC megger (Between live parts and the mounting part) | ||
| Vibration Resistance | 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions for 2 hours each (at power off) | ||
| Shock Resistance | 500 m/s² (Approx. 50 G) in X, Y and Z directions 3 times each (at power off) | ||
| Protection | IP50 | ||
| Case Material | ABS resin with glass | ||
| Connector | Connector : SM03B-GHS(3-pin)(from J.S.T. Mfg. Co., Ltd.) [Connections]Housing : GHR-03V-S, Contact : SSHL-002T-P0.2 (from J.S.T. Mfg. Co., Ltd.) |
||
| Weight | Approx. 4 g | ||
| Options (Sold Separately) |
Connector harness: CNH-GHR03S28-300 | ||
Detection Sensitivity
| Model | GIS-1 | GIS-1H | GIS-2 | GIS-3 | GIS-5 | GIS-7 | GIS-X3 | GIS-20 | |
|---|---|---|---|---|---|---|---|---|---|
| GIS-11 | GIS-1H1 | GIS-21 | GIS-31 | GIS-51 | GIS-71 | GIS-X31 | GIS-201 | ||
|
Detection-
Sensitivity
|
30 Hz | 1 G ± 25 % |
1.5 G ± 20 % |
2 G ± 20 % |
3 G ± 20 % |
5 G ± 20 % |
7 G ± 20 % |
10 G ± 20 % |
20 G ± 20 % |
| 100 Hz Reference |
1.9G ± 30 % |
3.0 G ± 25 % |
4.1 G ± 25 % |
6.4 G ± 25 % |
10.9 G ± 25 % |
14.9 G ± 25 % |
21.0 G ± 25 % (70Hz) |
27.2 G ± 25 % (50Hz) |
|
Reference Frequency Characteristics (Typical Example)

Dimensions/Connector Harness/Output Circuit
Outline Dimensions

Connector Harness(Sold Separately)

Output Circuit

Precautions During Use
- The case fastening should be at a torque of 0.32 N·m or less.
- The normal closed output type takes 300 ms maximum from power ON to output turn-ON.
- Thermal shock applied to the sensor during an abrupt temperature change can change the detection sensitivity.Ensure proper handling of the sensor.
- When using in a location where a sudden change of air pressure is likely, confirm that operation in that situation is satisfactory.
- Avoid subjecting the sensor wire harness to mechanical stress while connecting to the connector or allowingvibration to transferred from impact, otherwise disconnection or malfunction may result. Support the harness lead-out so that it is not subjected to excessive stress or vibration.
- Fix the harness pull-out part so that no stress or vibration from the harness is reaches the sensor.
- For other precautions during use, refer to the General Precautions for shock sensor.
* For other detailed specifications, refer to the specification sheet of the corresponding model.
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
| Model Name | Output configuration | Detection sensitivity | Standard Price | Inventory Type | Select |
|---|---|---|---|---|---|
| GIS-1 | Normally open | 1 G |
13 USD
12 EUR
|
STD | |
| GIS-1H | Normally open | 1.5 G |
13 USD
12 EUR
|
STD | |
| GIS-2 | Normally open | 2 G |
13 USD
12 EUR
|
STD | |
| GIS-3 | Normally open | 3 G |
13 USD
12 EUR
|
STD | |
| GIS-5 | Normally open | 5 G |
13 USD
12 EUR
|
STD | |
| GIS-7 | Normally open | 7 G |
13 USD
12 EUR
|
STD | |
| GIS-X3 | Normally open | 10 G |
13 USD
12 EUR
|
BTO | |
| GIS-20 | Normally open | 20 G |
13 USD
12 EUR
|
STD | |
| GIS-11 | Normally closed | 1 G |
13 USD
12 EUR
|
STD | |
| GIS-1H1 | Normally closed | 1.5 G |
13 USD
12 EUR
|
WIP | |
| GIS-21 | Normally closed | 2 G |
13 USD
12 EUR
|
STD | |
| GIS-31 | Normally closed | 3 G |
13 USD
12 EUR
|
STD | |
| GIS-51 | Normally closed | 5 G |
13 USD
12 EUR
|
STD | |
| GIS-71 | Normally closed | 7 G |
13 USD
12 EUR
|
BTO | |
| GIS-X31 | Normally closed | 10 G |
13 USD
12 EUR
|
BTO | |
| GIS-201 | Normally closed | 20 G |
13 USD
12 EUR
|
BTO |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.