Model MGP-C*701 High-sensitivity Electromagnetic Sensor
- Product catalog download
- 3D PDF Download
- MGP-C□701 Download the CAD data (DXF / Parasolid / STEP / IGES)
- MGP-CW701 Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- Magnet detection
- Automatic guided vehicles guidance
Features
- Uses a magnetism focusing construction (patented) that makes it particularly strong against ambient temperatures.
- The magnetism focusing construction is very useful as the sensor can detect at a long distance targets with a wide surface but a weak magnetic flux, like belt-shaped rubber magnets.
- N pole, S pole and Bipolar detection models are available. Select the model depending on your usage.
- Operation can be easily checked with the operation display light.
- Equipped with protection diodes to protect the sensor from reverse connection to the power supply and output surges.
- This is the equivalent of other company detection sensitivity 500μT.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating/Performance
Rating / Performance
Model | MGP-CN701 | MGP-CS701 | MGP-CW701 |
---|---|---|---|
Detection Surface | Front side detection | ||
Detection Sensitivity | 700 μT ± 100 μT | 700 μT ± 150 μT | |
Power Supply Voltage | 12 V to 24 V DC (Operating voltage range : 10 V to 30 V DC) | ||
Power Consumption | 20 mA DC or less | ||
Output | 30 V DC 50 mA DC or less NPN transistor open collector | ||
Output Residual Voltage | 1 V DC or less (Load current 50 mA DC) | ||
Operation Configuration | Normally open (On output with magnetic field) | ||
Operation Display | Red LED (Lit when On output) | LED Red with N pole detection Green with S pole detection |
|
Response Time | 300 μs or less | ||
Hysteresis | 75 μT or less (With a rubber plate magnet of 30 × 30 × t1.5 mm) |
100 μT or less (With a rubber plate magnet of 30 × 30 × t1.5 mm) |
|
Detection Polarity | N pole | S pole | N pole and S pole |
Reference Detection Distances |
42 mm (*The MG50-1 series) | ||
Operating Set Distance | 5 to 30 mm (*The MG50-1 series) | ||
Operating Temperature Range |
-10 to 60 °C (-20 to 65 °C during storage) (Without dew condensation or freezing) |
||
Operating Humidity Range |
90% RH or less (90% RH or less during storage)(Without dew condensation) | ||
Withstand Voltage | 1 min at 500 V AC 50/60 Hz (Between the live part and case) | ||
Insulation Resistance | 100 MΩ or more measured with an ohmmeter at 500 V DC (Between the live part and case) |
||
Vibration Resistance | Durability : 2 hours in each X, Y, Z direction at 10 to 55 Hz and with peak-to-peak amplitude of 1.5 mm (At power off) | ||
Shock Resistance | Durability : 3 times at 500 m/s² (approx. 50 G) in each X, Y, Z direction (At power off) |
||
Protection Rating | IP65 | ||
Case Material | ABS (Nut:ABS/PC composite) | ||
Cable | ø4 round cord of 0.2 mm² and 1 m in length (Oil and heat resistant) | ||
Number of Cable Core | 3-core | 4-core | |
Weight | Approx. 30 g |
External Dimensions Diagram/Output Circuit
External Dimensions Diagram
Output Circuit
Usage Precautions
- If there are magnetic objects on or around the installation location of the electromagnetic sensor, keep a distance between the sensor and these objects greater than the distance between the sensor and the magnet tape. Check also carefully the detection characteristics before using the sensor.
- If there is magnetic metal with residual magnetism in the surroundings of the electromagnetic sensor installation location, the detection characteristics may greatly vary. Verify the detection characteristics before using the sensor.
- Tighten the sensor using the nuts supplied with a torque of 0.5 Nm.
- See Electromagnetic sensor general usage precautions for other precautions.
Detection Area Diagram
Detection Area Diagram
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
Model Name | Detection polarity | Standard Price | Inventory Type | Select |
---|---|---|---|---|
MGP-CN701 | N pole |
38 USD
35 EUR
|
STD | |
MGP-CS701 | S pole |
38 USD
35 EUR
|
STD |
Model Name | Standard Price | Inventory Type | Select |
---|---|---|---|
MGP-CW701 |
50 USD
46 EUR
|
STD |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.