Model MAB-121N-0P5/0P10 High-sensitivity Analog Displacement Electromagnetic Guide Sensor
- Product catalog download
- 3D PDF Download
- MAB-121N-0P5/0P10 Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- Automatic guided vehicles guidance
Features
- An electromagnetic guide sensor for automatic guided vehicles (AGV) that outputs the right and left displacement from the magnet tape as an analog voltage.
- Can detect derailment using the derailment signal (open collector NO output).
- Can be used in a variety of environments with its plastic case filled with solid plastic and its IP67.
- Can control tiny movements in the width direction.
- Can be branch control of the left and right.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating/Performance/Branch Control/Characteristics Graph
Rating / Performance
Model | MAB-121N-0P5 | MAB-121N-0P10 |
---|---|---|
Detection Surface | Front side detection | |
Power Supply Voltage | 12 V to 24 V DC (Operating voltage range: 10 V to 36 V DC) Ripple 5% or less |
16 V to 24 V DC (Operating voltage range: 15 V to 36 V DC) Ripple 5% or less |
Power Consumption | 100 mA DC or less (With 12 V DC) 70 mA DC or less (With 24 V DC) |
80 mA DC or less (With 16 V DC) 70 mA DC or less (With 24 V DC) |
Analog Displacement Output |
0 V to 5 V DC (Output voltage when no magnetism) (Standard output voltage 2.5 V DC) Output impedance 3.3 kΩ |
0 V to 10 V DC (Output voltage when no magnetism) (Standard output voltage 5 V DC) Output impedance 3.3 kΩ |
Output Residual Voltage | 0.5 V DC or less (Load current 50 mA DC) | |
Derailment Alarm Output | NPN transistor open collector normally open 30 V DC 50 mA DC or less | |
Number of Detection Points and Pitch |
2 point / 120 mm | |
Response Time | 5 ms or less | |
Reference Detection Distances |
55 mm (*For the MG50-1 series) | |
Operating Set Distance | 30 to 45 mm (*The MG50-1 series) | |
Detection Polarity | N pole | |
Operating Temperature Range |
-10 to 60 °C (-20 to 70 °C during storage) (Without dew condensation or freezing) |
|
Operating Humidity Range |
95% RH or less (95% RH or less during storage)(Without dew condensation) | |
Withstand Voltage | 1 min at 500 V AC 50/60 Hz (Between the live part and case) | |
Insulation Resistance | 100 MΩ or more measured with an ohmmeter at 500 V DC (Between the live part and installation part) |
|
Vibration Resistance | Durability : 2 hours in each X, Y, Z direction at 10 to 55 Hz and with peak-to-peak amplitude of 1.5 mm (At power off) | |
Shock Resistance | Durability : 3 times at 500 m/s² (approx. 50 G) in each X, Y, Z direction (At power off) |
|
Protection Rating | IP67 | |
Case Material | Case : ABS, aluminum plate t1.5 (Anodized aluminum, black) | |
Cable | ø7.7, 7-core (shielded strands) round cord of 0.5 mm² and 1 m in length (Oil resistant) |
*For a detailed specification of the other, please refer to specifications.
Branch Control
L = 0 V connection, H = Terminal open
SEL1 | L | L | H | H |
---|---|---|---|---|
SEL2 | L | H | L | H |
Mode | Disabled | Left branch mode | Right branch mode | Straight mode |
*SEL 1 = L, SEL 2 = L disabled mode has a lock for the magnetic detection of the magnetic sensor. Please do not use absolutely
Diagram of Typical Analog Displacement Output
External Dimensions Diagram/Output Circuit
External Dimensions Diagram
Output Circuit
Adherence Matters/Usage Precautions
Adherence Matters
Branch control of analog displacement electromagnetic guide sensor, displacement analog data at the time of straight running of the branch signal input verge save the hold circuit arithmetic control. Therefore please use always observe the following things.
- Branch mode can not be used only after the straight-ahead running. Therefore after power is turned on is not a problem even for a short time. Please use the branch mode at a branch point before traveling in straight mode.
- Save time of displacement data when a branch mode input has become a approximately 3 hours.
Therefore after the branch mode input branches running within three hours, magnetic guide tape is running side is sure to return to the always straight mode once away from the detection range of the sensor. - SEL1 and SEL2 is the input of the branch control only.
Please note therefore both "L" and are not intended for use in the (GND connection).
Usage Precautions
- Be sure to control the running so that it follows the analog reference output voltage value.
- Our electromagnetic sensors have a low output protection resistor impedance to minimize detection measurement errors. Pay attention that noise or surge voltage does not damage the sensor. To extend the cables, use shielded wires and let the shielded part fall onto the frame of the vehicle body.
- See General usage precautions for automatic guided vehicles electromagnetic sensors for other precautions.
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
Model Name | Standard Price | Inventory Type | Select |
---|---|---|---|
MAB-121N-0P5 |
253 USD
234 EUR
|
BTO |
Model Name | Standard Price | Inventory Type | Select |
---|---|---|---|
MAB-121N-0P10 |
253 USD
234 EUR
|
BTO |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.