Model MPD-801(L) Magnetic Position Detection Sensor
- Product catalog download
- 3D PDF Download
- MPD-801 Download the CAD data (DXF / Parasolid / STEP / IGES)
Application
- X · Y slide table origin detection for machine tools
- Origin detection angle of the rotating body
- For detecting position of closing elevator door
- Sealed for detection of precision equipment and safe
Features
- Highly stable operation even when the ambient temperature varies thanks to its magnetism focusing construction (patented).
- Response at high speed is possible.
- It is a high accuracy and repeatability ± 100 μ or less.
- If used near a set distance, repeatability will be even higher.
International Standards
- Our products do not have overseas safety regulations such as CE mark, UL standard, EN standard etc.
- Products is compliant to the RoHS directive.
* Please consult about "change of specification" and "request of specification" of the product.
Rating/Performance
Rating / Performance
Model | MPD-801 | MPD-801L |
---|---|---|
Detection Surface | Front side detection | |
Detection Function | Switch (Normally) detection | Latch detection |
Set Distance | 3 mm ± 1 mm | |
Detection Sensitivity | 800 μT or more | |
Standard Detection Target |
MG10-10-BHT | |
Repeat Accuracy 1 | ± 30 mm or less detection position error (Set distance at a constant) | |
Repeat Accuracy 2 | Detecting position error is or less ± 100 mm (3 mm ± 1 mm when set distance at a constant) |
|
Power Supply Voltage | 10 V to 26.4 V DC | |
Power Consumption | 15 mA DC or less | |
Output | 30 V DC 50 mA DC or less Nch MOSFET open drain | |
Operation Configuration | Normally open (On with magnetic field) | |
Operation Display | ON S pole detection, red LED lights | |
Response Time | 50 μs or less | |
Operating Temperature Range |
-10 to 60 °C (-20 to 70 °C during storage) (Without dew condensation or freezing) |
|
Operating Humidity Range |
95% RH or less (95% RH or less during storage)(Without dew condensation) | |
Withstand Voltage | 1 min at 1500 V AC 50/60 Hz (Between the live part and case) | |
Insulation Resistance | 100 MΩ or more measured with an ohmmeter at 500 V DC (Between the live part and installation part) |
|
Vibration Resistance | Durability : 2 hours in each X, Y, Z direction at 10 to 55 Hz and with peak-to-peak amplitude of 1.5 mm (At power off) |
|
Shock Resistance | Durability : 3 times at 500 m/s² (approx. 50 G) in each X, Y, Z direction (At power off) |
|
Protection Rating | IP67 | |
Case material | ABS | |
Cable | ø4, 3-core round cord of 0.3 mm² and 1 m in length (Oil and heat resistant) |
|
Weight | Approx. 33 g |
External Dimensions Diagram/Output Circuit
External Dimensions Diagram
Output Circuit
Usage Precautions
- In the case in which the output is set to ON, please attach the magnet N → S to pass through without fail.
- Since the MPD-801L is are to have a self-holding function, you can hold the work until you detect the N pole after the output is ON by detecting the S pole. Therefore please let detect the N pole to the sensor in order to be reversed (OFF) the output signal.
It is not possible to hold the operating state self-holding circuit that was ON and turn OFF the power. Therefore please be aware of this power outage output it will be a state of being OFF until it detects the power is turned on again after the S pole. - Please use a combination of standard detector, and MG10-10-BHT form must be our magnetic sensor.
In addition, it is set so that the center of the standard proximity body to pass through N → S, and S → N the center portion of the sensor detection surface, the distance between the sensors and the standard detection body as to translate 3 ± 1mm within Please use. - This magnetic sensor is highly sensitive because of the use of a patented magnetic convergence mechanism.
Material of the mounting portion of the standard sequence detector sensor to avoid magnetic metal, please use by using a material of a non-magnetic material.
Also, please use on your consideration enough the impact if there is a magnetic metal around. - See Electromagnetic sensor general usage precautions for other precautions.
Detection Characteristic
*After you have put an item in your shopping cart, choose either [Quote] or [Order].
*For customized products or specifications, contact us using "Inquiry."
*Choose the currency from JPY, USD, or EUR.
Model Name | Detection function | Standard Price | Inventory Type | Select |
---|---|---|---|---|
MPD-801 | Switch detection |
28 USD
26 EUR
|
BTO | |
MPD-801L | Latch detection |
28 USD
26 EUR
|
BTO |
STD Shipping is available immediately (on the day of order)
WIP Shipping is available within 1 to 3 weeks
BTO Shipping is available within 10 to 18 weeks
NOTE: The above information shows the typical delivery time. For actual delivery time, please confirm us as it depends on our business days and/or product quantities.
In the case of the quote request and order, please be sure to check the Terms and Conditions.
If you have made the procedure of quote request and order, it assumes that agree to the Terms and Conditions.